Dealer and Supplier For Laboratory & Industrial Chemicals, Scientific Instruments, Glasswares, Plastic wares, Filters, Safety Equipments, Pharmaceuticals Instruments, machinery & many more...

For more Information

JASHBIN ENTERPRISES now enters into the medico-para medico, surgical industries. We deal for the instruments and reagents also. Some of them....

INSTRUMENTS :

Biochemistry : 

Semi automated from SEAC, ITALY - Star-21

Batch Analyzer from AME, ITALY - Autolab 

Random Access, Fully automatic - AMS ITALY - LIASYS

Elisa :

Strip Reader from DAS, ITALY.

Plate Reader from Radim Group Italy - Sirio

Fully automatic from Radim Group Italy - Brio.

Clotting :

Single channel from Sigma USA.  - KC-1

Four channel from Sigma USA.  - KC-4

AMAX Destiny

Electrolyte : 

AUTOMATED ELECTROLYTE ANALYZER FOR Na, K, Li  from SEAC. Italy - FP-20.

Nyco card reader II :
For HBA1C, U-Albumine, CRP, D-Dimer. Quantitative.
Urine Analyzer : 
Uritek 151, Uritek 720 from Teco, USA.

 

TOP

Reagents :

Biochemistry:

From Sigma USA

Teco, USA Monovials/Bulk Packs.

Dialab Austria - Liquid ChemistryHome

Elisa :

Radim Group Italy

Teco USA

Adaltis, Canada.

 

Spot Tests :

HCG, HbsAg, HIV, HCV, Maleria from ACON

Serology, Antisera, VDRL, RF, ASO, CRP

Urine Strips : 

Teco USA (from 1 to 10 parameters)

.

Troponine I :

ANI Finland

Coagulation : 

Sigma USA.

Others :

Lancets, Prickers, Swabs,

   

TOP

CLINICAL CHEMISTRY AUTO ANALYZER :

The new Clinical Chemistry analyzer Star 21 is the basic Instrument for any type of laboratory, ambulatory or hospital ward: It effects reading in end point, kinetic, fixed time and differential, in absorbance and concentration, with standard from 1 to 9 or K factor.

The memory contains 199 methods with the possibility to program, for each method, the type of reaction, wavelength, temperature, reading unit, normal values, aspiration volume, incubation time and reading intervals.

The instruments is  completed with LCD for the operator through the programming phases, a cuvette chamber for the thermostatic control of samples, a touch pad alphanumerical keyboard, a reading chamber for sample reading and an incorporated graphical printer for the print out of data, calibration and kinetic curves.   

Readings effected on flow thro cells or single cuvettes, 10 x 10 mm  in mono and bichromatism.

Open system for all type of clinical chemistry tests on sera, plasma and whole blood.

The analyzer for all needs, from routine to urgencies, from small to large laboratories.

Weight : 9.0 Kg.

TOP

 

AN INTELLIGENT AUTOMATED SYSTEM

AUTOLAB

TEST MENU :
SUBSTRATES
ENZYMES
HOMOGENEOUS IMMUNO ASSAYS
URINALYSIS
ENZYMATIC ELECTROLYTES

 

FULLY AUTOMATED COMPUTERIZED BENCH TOP MODEL

FULLY OPEN SYSTEM

TYPE - SELECTIVE MULTIBATCH.

THROUGHT - 200 TESTS/HR.

PATIENT & TESTS ORIENTED REPORT. 'PATIENT ENTRY' DURING OPERATION

WAVELENGTH 340 TO 700 & 1 DARK FILTER

BUILT IN DILUTOR WITH HIGH PRECISION MICRO PROCESSOR CONTROLLED.

SEPARATE POSITION FOR STANDARD AND CONTROLS.

REAGENT VOLUME - 400-500 ul

REUSABLE REACTION CELL

50 DIFFERENT TESTS, PARAMETERS ALL USER PROGRAMMABLE. (26 TESTS PER SAMPLES)

9 PROFILE WITH 19 TESTS EACH.

PRE DILUTION & REPETITION  IN "AUTO DILUTION" MODE.

IBM COMPATIBLE PC. RS232C INTERFACE. INTERNAL PRINTER.

23 AUXILIARY PROGRAM, BUILD IN CLOCK AND CALENDAR.

MONITORING OF REAGENT VOLUME BY COMPUTER.

EXTENSIVE QUALITY CONTROLLED. GRAPHICAL DISPLAY OF Q.C. RESULTS

PROGRAMMABLE AUTOMATIC WASH BETWEEN SAMPLES AND TESTS RUN.

MONITORING OF REACTION CURVE FOR PATIENT SAMPLE

DATA TRANSFER TO HOST COMPUTER

HARD DISK MANUAL MODE FOR ABSORBANCE MEASUREMENTS.

IMMUNO ASSAYS & URINALYSIS ALSO POSSIBLE.

COMPREHENSIVE ERROR CODE HANDLING. ERRORS AUTOMATICALLY FLAGGED.

TOP

CLINICAL CHEMISTRY ANALYZER  

LIASYS :

FULLY AUTOMATED - RANDOM ACCESS, CONTINUOUS LOADING, BENCHTOP  ANALYZER FOR CLINICAL CHEMISTRY AND IMMUNOTURBIDIMETRIC ASSAYS.

ASSAY TYPE : END POINT, KINETIC DIFFERENTIAL, BICHROMATIC AND  IMMUNOTURBIDIMETRIC ASSAYS; UP TO 100 DIFFERENT TESTS, ALL USER PROGRAMMABLE.

TEST ENTRY MODE : SELECTIVE - PROFILE BATCH - STAT

ON LINE REAGENT : 2 RACKS COOLED BY PELTIER CELLS ARE PROVIDED TO CONTAIN UP TO 20 REAGENTS.

            2 RACK FOR 13 REAGENTS POSITIONS AT ROOM TEMPERATURE. 14 STANDS AND CONTROLS.

            2 MORE POSITION FOR DILUTENTS.

SAMPLE LOADING : 5 RACKS FOR CONTINUES LOADING OF SAMPLES SPLIT IN  :

            64 POSITIONS FOR ROUTINE SAMPLES

            14 POSITIONS FOR STAT SAMPLES.

PRIMARY TUBES SIZE:   MAX Ř 16 X 100

STAT SAMPLE S PROCESSING: ALLOWED AT ANY TIME

THROUGHPUT : 200 TESTS /HR. WITHOUT ISE.

WORKING TEMP. 370C

READING SYSTEM : DIRECT PHOTOMETRY

MINIMUM REACTION VOLUME : 300ul

OPTIC SYSTEM :

PHOTOMETER : MULTI - WAVELENGTH OPTICS

WAVELENGTH : 8 NARROW BAND INTERFERENTIAL FILTERS

LIGHT SOURCE : HALOGEN LAMP 6V/10W

OPTICAL PATH : 10mm

LINEAR RANGE : 0.001 ÷ 2.500 Abs

RESOLUTION : 0.0001 Abs.

SAMPLING ARM : ONE MECHANIC ARM PROVIDES ALL SAMPLING OPERATION WITH :

            CAPACITIVE LIQUID LEVEL SENSING

            REAGENT PRE WARMING AT 370C.

            AUTOMATIC PROBE WASHING.

DILUTOR : DILUTIONS ARE MADE WITHOUT USING TRADITIONAL SYRINGES WITH THE FOLLOWING SPECIFICATIONS:

            SAMPLE VOLUME : 2.0 ul ÷ 50 ul (1 ul INCR.)

            REAGENT VOLUME : 25 ul ÷ 400 ul (1 ul INCR.)

REACTION PLATE : CIRCULAR 60 SEMI -DISPOSABLE CUVETTES TRAY WITH FOLLOWING CHARACTERISTICS:

            AUTOMATIC CUVETTE WASHING

            CUVETTES Q.C. CONTINUOUSLY COMPUTER CONTROLLED

            INCUBATION TEMP. 370C.

IBM COMPATIBLE COMPUTER.

TOP            

SCREENING TEST

HCG Devices & Strips

TRUE ONE STEP TEST

Use the plastic pipette, dispense 3 drops of urine or serum sample in to the sample well.

Read result in 3-5 minutes.

RELIABLE & CONVENIENT

Accurate and reliable

Clear background & sharp line

Result in just 5 minutes

Easy to use

Room temperature storage

Immerse the strip in the urine & serum sample till the arrow mark indicated

Read result in 3-5 minutes,

Easy TO INTERPRET

SENSITIVITY

Urine/Serum Sample                         25mlU/ml

TOP

HIV, HCV, HBsAg :

SCREENING TEST:

UNIQUE LATERAL FLOW TESTS

CONVENIENT ,ACCURATE & RELIABLE 

SENSITIVE & SPECIFIC

HIV, HCV, HBsAg :

HIV :

Double Antigen Sandwich Method

Recombinant HIV Antigens

GP 36, 41&120 Used

Sensitivity => 99.5%

Specificity = 99.6%

In built control Provided

Sample :

Format I : Whole Blood /Serum/plasma

Format II- Serum /Plasma

HCV :

Double Antigen Sandwich Method

Recombinant HCV Antigens

Sensitivity =99.9%

Specificity = 99.6%

In built control provided

Sample :

Format I : Whole Blood /Serum/plasma

Format II- Serum /Plasma

 

HBsAg :

Two –Site sandwich immunoassay

Sensitivity 0.5ng/ml

In built control provided

sample : 

Format I : Whole Blood /Serum/plasma 

Format II- Serum /Plasma

 

 

TEST

PACK SIZE

HIV-DEVICE

10 TEST & 40 TEST

HCV-DEVICE

HCV STRIP

u

HbsAg DEVICE

HbsAg STRIP  

40 TESTS

50 TESTS

Storage : Device :-                 4-300C

                  Buffer Vial   : -        2-80C

Sr. No.

Product

Pack size

 

 

 

1

Pregnancy test

50 Strips

 

 

40 Cards

2

HBsAg test

50 Strips

 

 

40 Cards

3

HIV –Whole blood

10 T

 

 

40T

4

HIV-Serum/plasma

10T

 

 

40T

5

HCV-Whole blood

10T

 

 

40 T

6

Maleria test

10 T

 

 

40 T

7

Syphilis test

50 T

Syphilis :

Diagnose Syphilis by detecting antibodies (IgG & IgM) to Treponema Pallidum (TP) Qualitatively in serum / plasma or whole blood accurately & conveniently.

Kit Size : 50 Strips

Features :

  Features  
  Test Principle Immuno (IgG & IgM) Chromatography
  Procedure Time 10 Minutes
  Interpretation Very Easy
  Sensitivity 99.9%
  Specificity 99.7%
  Inbuilt Control Yes
  Shelf Life 24 Hours
  Storage Room Temp.

TOP

NYCOCARD READER :

NycoCard HbA1c :

NycoCard HbA1c Determines

the quality of metabolic control

DETERMINES THE QUALITY OF METABOLIC CONTROL

THE IMPORTANCE OF METABOLIC CONTROL

SEVERAL STUDIES HAS SHOWN THE IMPORTANCE OF METABOLIC CONTROL IN PREVENTING AND SLOWING THE PROGRESSION OF DIABETIC LATE COMPLICATIONS   FOR PERSON WITH THE TYPE I 1 (DCCT )STUDY  AND TYPE II (UKSPD0 DIABETES .MEASUREMENTS OF GLYCATED HAEMOGLOBIN HAS PROVEN TO BE AN IMPORTANT TOOL IN DETERMINING THE QUALITY OF THE METABOLIC CONTROL

TIME SAVING FOR YOU AND YOU PATIENTS

NYCOCARD Hba1C IS RAPID AND PROVIDES AN ACCURATE Hba1C RESULT WITHIN THREE MINUTES DURING THE PATIENT

CONSULTATION – MAKING A REVISIT TO ALTER THE TREATMENT REGIME NO LONGER NECESSARY.

STANDARDIZATION :

THE INTERNATIONAL FEDERATION OF CLINICAL CHEMISTRY (IFCC) HAS ESTABLISHED A WORKING GROUP ON  GLYCO HEMOGLOBIN STANDARDIZATION .THIS WILL BE BASED  ON HbA1C   AS IT IS THE EASIEST COMPONENT TO DEFINE. METHODS THAT MEASURE TOTAL HEMOGLOBIN, SUCH AS AFFINITY METHODS CAN ALSO BE STANDARDIZED AGAINST HbA1C AS THEIR RESPECTIVE VALUES CORRELATE WELL. 

NYCOCARD HbA1C IS STANDARDIZED ACCORDING TO THE RECOMMENDATIONS TO THE ERL LABORATORY (EUROPEAN REFERENCE LABORATORY) DCCT LEVEL AND IS CERTIFIED IN ACCORDANCE WITH THE ERL CHECK UP PROTOCOL.  

NO INTERFERENCE OF HEMOGLOBIN VARIANTS OF DERIVATIVES

FEATURES    :

NYCOCARD READER FOR QUANTITATIVE DETERMINATION

NYCO CARD READER IS USING FOR FOUR TEST

 

 

Hb A1c

U-ALBUMIN

CRP

D-DIMER

Hb A1c TEST RESULT WITHIN   3 MINUTES

 

TIME SAVING FOR YOU AND YOUR PATIENTS

 

Hb A1c CHARACTERISTICS  

MEASURING RANGE  : 3-18% Hb A1c
REFERENCE RANGE : 4.5-6.3% Hb A1c
SAMPLE MATERIAL    : 5 u L   BLOOD
PRECISION :

A COEFFICIENT OF VARIATION (CV) BELOW 5% BOTH WITHIN AND BETWEEN RUN

                                                     

 

 TOP

 

NycoCard U-Albumin(Microalbumin)

 

NycoCard U-Albumin(Microalbumin)

Pin - point patients at risk

NYCOCARD U ALBUMIN (MICRO ALBUMIN )

PIN POINTS PATIENTS AT RISK 

WHY MEASURE URINARY ALBUMIN CONCENTRATIONS? 

DIABETIC NEPHROPATHY IS A FREQUENT AND SECONDARY COMPLICATION OF DIABETICS MELLITUS, LEADING TO INCREASED MORBIDITY AND MORTALITY, AND TO IMPAIRED QUALITY OF LIFE IN PERSON AFFECTED.  EARLY DETECTION OF  THE DISEASE, AT THE STAGE OF MICROALBUMUNURIA IS IMPORTANT FOR ITS OUTCOME AND PROGRESSION. IF APPROPRIATE MEASURES ARE TAKEN, MICROALBUMINURIA CAN  BE HALTED OR EVEN REVERSED .

MICROALBUMUNURIA IS DEFINES AS A PERSISTENT ELEVATION OF THE URINARY ALBUMIN EXCRETION TO 20-200 ug /MIN OR 20 TO 200 mg/L WHEN USING EARLY MORNING URINE.

STUDIES HAVE DEMONSTRATED THAT MICROALBUMUNURIA INDEPENDENTLY PREDICTS CARDIOVASCULAR MORBIDITY AND ALL CAUSE MORTALITY IN ESSENTIAL  HYPERTENSION. MONITORING OF MICROALBUMUNURIA IS WORTH WHILE IN ORDER TO MONITOR THE EFFECT OF ANTI HYPERTENSIVE TREATMENT ON TARGET ORGAN DAMAGE 

LOW PROTEINS DIET, LOWERING BL0OD PRESSURE AND THE USE OS ANTI HYPERTENSIVE THERAPY HAVE ALL BEEN REPORTED TO HAVE A POSITIVE EFFECT ON DECREASING THE URINARY ALBUMIN EXCRETION .THE DCCT RESEARCH GROUP HAS SHOWN THE IMPORTANCE  OF STRICT GLYCAEMIC CONTROL N PREVENTING MICROALBUMUNURIA

NYOCARD U ALBUMIN IS SIMPLE QUICK AND CONVENIENT – WITHIN ONLY THREE MINUTES A QUANTITATIVE TEST  RESULT IS OBTAINED USING THE NYCOCARD READER II

                                                      

                                                       

                                                                          

U ALBUMIN CHARACTERISTIC    

 

MEASURING RANGE : 5-200mg /L Albumin
SAMPLE MATERIAL : 50Ul urine
Test principle

: Solid phase SANDWICH - FORMAT, Immunometric assay using a gold Antibody conjucate.

PRECISION :  IN CONTROLLED LABORATORY TESTING A COEFFICIENT OF VARIATION (CV) OF 5-8% IS USUALLY OBTAINED

 

NYCOCORD READER II ONE

INSTRUMENT FOUR TEST

AVAILABILITY :

1100296   NYCOCARD u albumin .24  test

1109959   NYCOCARD   ui albumin control, 2 x 1.0 ml

1042184   NYCOCARD   HbA1c ,24 TEST

1113022    NYCOCARD   HbA1c   CONTROL, 2 X 0.4ML

1047778    NYCOCARD   READER II KIT

   
  HbAc
  Microalbumin
  D- Dimer
  C-Creative protein

 

TOP

ANALYZER / READER FOR URINE ANALYSIS :

URITEK   151

COMPACT  & EASY TO USE :

MULTI STRIP READER

URITEK 151 IS A COMPACT, STATE OF THE ART URINE REAGENT STRIP READER FEATURING 

THROUGHPUT IS 120 TEST 120/HR

500 RESULTS STORAGE CAPACITY

IN BUILT THERMAL PRINTER

URS 8 TO URS 11 TEST SELECTION FUNCTION

AMBIENT OPERATING TEMPERATURE RANGE ROOM TEMPERATURE

 URITEK 720

MULTI STRIP READER

URITEK 720 IS A COMPACT, STATE OF THE ART URINE RAEGENT STRIP READER FEATURING

THROUGHPUT IS 720 TEST /HR

AUTOMATIC FEEDING OF STRIPS

2000 RESULTS STORAGE CAPACITY

IN BUILT THERMAL PRINTER AND AUDIO ALARM

URS 2 TO URS 11 TEST SELECTION FUNCTION

LCD 8 LINER 40 CHARACTER

AMBIENT OPERATING RANGE   ROOM TEMPERATURE

 

 

TOP 

 

STRIP READER :

ELISA / EIA READER :

STRIP READER IS A ANALYSER TO READ ELISA MICROWELL STRIPS WITH 8/12 WELLS OR PART OF THEM. DESIGNED ACCORDING TO THE MOST SOPHISTICATED TECHNOLOGIES IT TURNS OUT TO BE OUT OF TOP QUALITY AND RELIABILITY AS WELL AS OF HIGH PRECISION  AND USER FRIENDLY. BY ITS POWERFUL SOFTWARE IT IS ABLE TO PROCESS AND STORE READING AND COMPLEX DATA

TECHNICAL FEATURES :   

OPTICAL READING 0.000-4.000 OD
ACCURACY ± 1%  FROM 0.000 TO 1.500 OD
LIGHT SOURCE TUNGSTEN LAMP ,CONSUMPTION                    AUTOMATICALLY REDUCED IN STAND  BY POSITION
OPTICAL FILTERS 405, 450, 492, 630 nm (3 MORE OPTIONAL)
DETECTOR SILICON PHOTODIODE 
CUVETTE   MICRO STRIPS WITH 8 OR 12 WELLS
DISPLAY 2 LINES WITH 16 COLUMNS
PRINTER 20 COLUMNS THERMAL PAPER
KEYBOARD 17 BUTTONS
CALCULATION MODE

OD SINGLE CALIBRATOR ,DIRECT OR CALCULATED CUT  OFF, PROGRAMMABLE  FROM  2 UP TO 7 POINTS.

MEMORY CAPACITY UP TO 100 DIFFERENT TESTS
CURVES DIRECT POINT TO POINT CALIBRATION PRINTING
TEST MENU

WIDEST RANGE OF ELISA TEST :

HIV,HCV AND HBs Ag

T3 .T4 AND TSH

TORCH

AND ALL  OTHER ELISA ANALYSES

CALENDAR / TIMER 

DATA/HOUR ASSOCIATED WITH RESULT , TIMER FUNCTION

INTERFACE    RS232 SERIAL PORT
WARM UP TIME 15 MINUTES
POWER SUPPLY 220/115 VAC 50/60 HZ 25 W
MEASUREMENTS      

CM 34 X 27 X 12

WEIGHT  KG 5,8

 

URINE REAGENT STRIPS

HIGH SPECIFIC AND SENSITIVE

SEMI QUANTITATIVE AND QUALITATIVE

STRIPS CAN BE READ MANUALLY/URINE STRIP READER

COST EFFECTIVE

SR. NO.

PRODUCT

PACK SIZE IN STRIPS

1

GLUCOSE

100

 

 

50

2

GLUCOSE-PROTEIN

100

3

GLUCOSE, KETONE

100

4

GLUCOSE PROTEIN, pH

100

5

GLUCOSE PROTEIN, pH Sp gravity

100

6

GLUCOSE PROTEIN, pH Biliburin, blood, uroblinogen Nitrite, ketone

100

7

GLUCOSE PROTEIN, pH Biliburin, blood, uroblinogen, Nitrite, Ketone, Leukocyte

100

           

TOP

IMMUNO - ASSAY ANALYZER (ELISA)

PLATE READER :

SPECIAL FEATURES OF AUTOMATIC ELISA SYSTEM BRIO

FULLY OPEN SYSTEM TO ANY ELISA

OPERATES SIMULTANEOUSLY ON 4 MICRO PLATES

120 SAMPLES PER RUN AND 384 TEST AR A TIME

9 DIFFERENT ASSAYS AT  A TIME

ALL OPERATING FUNCTIONS . DILUTION DISPENSING ,INCUBATIONS AND WASHING ARE AUTOMATIC

INCUBATIONS  FROM 25-45 DEG C (WITH 2DEG C INTERNAL)

INDIVIDUAL SHAKING (TYPE AND TIME )INDIVIDUAL INCUBATION FOR EACH PLATE IS POSSIBLE

MULTIFUNCTIONAL ARM (DISPENSIVE NEEDLE +WASHING MANIFOLD)

POSSIBILITY TO CONNECT  TWO BRIO ON LINE

DILUTION UNIT WITH 2 PRECISION SYRINGES

MULTI DISPENSING SYSTEM WITH CAPACITIVE LEVEL FLUID DETECTOR

ORIGINAL DOUBLE WASHING SYSTEM (ACTIVE EXTERNALLY AND INTERNALLY)

SOFTWARE BASED INSTRUMENT FUNCTIONING

REAGENTS KIT  VIAL DIRECTLY FITTING  ON BRIO REAGENT TRAY

 

SR. NO. PRODUCT MFG BY PACK SIZE IN TEST

1

HIV 1/2

BIOCHEM CANADA

192  

 

HIV ˝

BIOCHEM CANADA

960

2

HCV

BIOCHEM CANADA

192

 

HCV

BIOCHEM CANADA

960

3

TOXO LGM

UBI ,USA

48

4

RUBELLA LGM

UBI ,USA

48

5

CMV LGM

UBI ,USA

48

6

HERPES 2   LGM

UBI ,USA

48

7

TOXO LGM

UBI ,USA

96

8

RUBELLA LGM

UBI ,USA

96

9

CMV LGM

UBI ,USA

96

10

HERPES 2   LGM

UBI ,USA

96

11

TOXO LGM

RADIM ,ITALY

96

12

RUBELLA LGM

RADIM ,ITALY

96

13

CMV LGM

RADIM ,ITALY

96

14

HERPES 2   LGM

RADIM ,ITALY

96

15

TOXO LGG

UBI.USA

48

16

RUBELLA LgG

UBI.USA

48

17  

CMV LGM

UBI.USA

48

18 

HERPES 2LgG

UBI.USA

48

19 

TOXO LgG

UBI, USA

96 

20

RUBELLA LgG

UBI  USA

96

21

CMV LgG

UBI  USA

96

22

HERPES 2LgG

UBI USA

96

23

TOXLgG

RADIM ITALY

96

24

RUBELLA LgG

RADIM ITALY

96 

25

CMV LgG

RADIM ITALY

96

26

HERPES 2LgG

RADIM ITALY

96

27

H PYLORI LgG

UBI, USA

48

 

 

UBI, USA

48

 

 

RADIM ITALY

96

 

.

ADALTIS ITALY

96

28

T PALLIDIUM LGG

UBI USA

48

29

CYSTIRCERCOSIS

UBI USA

96

 

 

UBI USA

48

30

LH

UBI USA

48

31

FSH

UBI USA

48

32

PROLACTIN

UBI USA

48

33

hCG

UBI USA

48

34

HGH

UBI USA

48

35

TESTOSTERONE

UBI USA

48

36

PROGESTERONE

UBI USA

96

37

LH

.UBI USA

96

38

FSH

UBI USA

96

39

PROLACTIN

UBI USA

96

40

LH

ADALTIS ITALY

96

41

FSH

ADALTIS ITALY

96

42

PROLACTIN

ADALTIS ITALY

96

43

hCG

UBI USA

96

44 

TOTAL H CG

RADIM ITALY

ADALTIS ITALY

96

96

45

HGH

UBI USA

96

46

TESTOSTERONE

UBI USA

96

47

PROGESTERONE

UBI USA

96

48

ESTRADIOL

ADALTIS ITALY

96

49

DHEAS

ADALTIS ITALY

96

50

ANA

UBI USA

48

51

Ds DNA

UBI USA

48

52

ANA

UBI USA

96

53

Ds  DNA

UBI USA

96

54

PSA

UBI USA

48

 

 

 

96

55

AFP

UBI USA

48

 

 

 

96

56

PAP

UBI USA

48

 

 

UBI USA

96

57

FERRITIN

UBI USA

48

 

 

UBI USA

96

 

 

UBI USA

96

58

CORTISOL

UBI USA

48

 

 

UBI USA

96

59

CEA

UBI USA

48

 

 

UBI USA

96

 

 

RADIM ITALY

96

 

 

RADIM ITALY

96

60

CA 15 3

UBI USA

48

 

 

UBI USA

96

 

 

RADIM ITALY

96

 

 

ADALTIS ITALY

96

63

CA 24 2

RADIM ITALY

96

 

 

ADALTIS ITALY

96

64

RF LgM

UBI USA

48

 

 

UBI USA

96

65

MICRO ALBUMIN

UBI USA

48

 

 

UBI USA

96

66

IGE

UBI USA

96

67

BETA HCG

UBI USA

96

68

Hcg VISUAL

UBI USA

96

69

CA242

UBI USA

96

70

PROTEIN C

UBI USA

96

71

PROTEIN S

UBI USA

96

72

ZETA GLOBULIN

UBI USA

96

73

C PEPTIDE

UBI USA

96

74

INSULIN

UBI USA

96

75

T3

RADIM ITALY

96

76

T4

RADIM ITALY

96

77

TSH

RADIM ITALY

96

78

FREE T 3

ADALTIS ITALY

96

79

FREE T4

ADALTIS ITALY

96

80

TSH ULTRASENSITIVE

ADALTIS ITALY

96

81

ANTI HBC AGLGM

RADIM ITALY

96

82

ANTI HB s AG

RADIM ITALY

96

83

ANTI HB s AG  QTY

ADALIS ITALY

96

84

ANTI HB s AG

ADALTIS ITALY

96

85

ANTI HB s AG

RADIM ITALY

192

86

ANTI HbeAG/AB

RADIM ITALY

96

87

HB eAG

ADALTIS ITALY

96

88

ANTI CORE LGM

ADALTIS ITALY

96

89

HDV Ag

ADALTIS ITALY

96

90

ANTI HAV LGM

ADALTIS ITALY

96

91

HEV LGM

ADALTIS ITALY

96

92

DENGUE LGM

RADIM ITALY

96

93

DENGUE LGG

ADALTIS ITALY

96

94

TB IgG

RADIM ITALY

96

95

AFP

RADIM ITALY

96

96

ANTICARDDIOPLIN LGM

ADALTIS ITALY

96

97

ANTICARDDIOPLIN LgG

ADALTIS ITALY

96

98

TOTAL LgE

ADALTIS ITALY

96

 

TOP

 

AUTOMATED ELECTROLYTE ANALYZER FOR Na, K, Li 

FEATURES OF SODIUM ,POTASSIUM AND LITHIUM (FP  2O)

MAIN CHARACTERISTICS: 

1            AUTOMATIC STAT UP

2            AUTONOMOUS AIR SUPPLY

3            DOUBLE GAS LINE SECURITY SYSTEM

4            BUILT IN DILUTOR

5           AUTOMATIC STANDARDIZATION WITH MEMORIZATION OF THE  REFERENCE VALUE

6            SIMULTANEOUS READING FOR SODIUM AND  POTASSIUM WITH LITHIUM STANDARD

7            AUTOMATIC READING OF LITHIUM WITH INTERNAL K STANDARD

8            SOUND AND PICTURES SIGNATURE FOR ALARM AND WARNING

9            RESULT ON LCD

10        BUILT IN PRINTER

TECHNICAL CHARACTERISTICS : 

1. READING FIELDS :

SERUM : NA   0-250  mEQ/L

                 K      0-10    mEQ/L

                 LI      0-2.5   mEQ/L

URINE   : NA    0.250  mEQ/L

                 K       0.250  mEQ/L

2. MEASURING SYSTEM : 

AUTOMATIC  ZERO SETTING WITH BLANK INSERTION

3. GAS SUPPLY :  COMMERCIAL PROPANE GAS
4. WORKING  VOLUME : 

ASPIRATED SAMPLE  VOLUMES  50 ML

EROGATED  DILUENT  VOLUME  10 ML

5. DILUTION RATIO : 

1:200 FOR NA AND K

1: 20  FOR LITHIUM

6. RESULT TIME :  < 15 SEC
7. DISPLAY :  LCD: 4 LINES  X 20 COLUMNS
8. PRINTER :  THERMAL, 20 COLUMNS

TOP

ANALYSIS FOR CLOTTING ASSAYS :

KC1 SINGLE CHANNEL :

Manufactured by SIGMA - AMELUNG, USA

Auto start testing

Half - Volume PT and APTT testing for significance savings

Flexible instrumentation to simplify both routine and STAT testing.

Full range of clotting assays.

Patented Ball Method clot detection using half volumes.

Individual cuvettes for all test.

One test position with four cuvettes for sample preparation at 3700C.

Open system.

Reporting in time, % activity & INR.

Automatic INR calculation

KC1 may be operated with or without a printer.

KC4 FOUR CHANNEL :

Manufactured by SIGMA - AMELUNG, USA

Auto start testing

Half - Volume PT and APTT testing for significance savings

Flexible instrumentation to simplify both routine and STAT testing.

Full range of clotting assays.

Patented Ball Method clot detection using half volumes.

Preparation Area at room temp. for 12 samples with

Individual cuvettes for all test.

Incubation area at room temp. at 3700C, eight samples five reagents, & two pipettes..

Open system.

Complete data management.

Programmable single and duplicate tests.

KC4 may be operated with or without a printer.

TOP

AMAX Destiny :

ACCURATE :
TRUE CLOT DETECTION - CORRECT TIME RESULT FIRST TIME.

SECURE :

UNIQUE SAMPLE MANAGEMENT WITH ABSOLUTE VERIFICATION OF SAMPLE POSITIONING

USER ID LOG ON OPTION

INTUATOUCH OPERATION :

INTUITIVE, ICON PROMPTED SOFTWARE

TOUCH SCREEN OPERATED

EASY TO LEARN - TOTAL RECALL

ONE TOUCH REAGENT MANAGEMENT

INFINITE POSSIBILITIES:

STAT ON ANY SAMPLE POSITION

30 REAGENT STORAGE POSITION

UNLIMITED NUMBER OF DEFINED TESTS. TESTS/SAMPLES.

SIMULTANEOUSLY - CLOTTING, CHROMOGENIC, IMMUNOLOGICAL 

CONCURRENT - CALIBRATION AND SAMPLE PROCESSING

PARALLELISM - MULTIPLE DILUTIONS/SAMPLES.

REFLEXIVE TESTING :
USER DEFINABLE AUTO REPEAT RANGES
USER DEFINABLE AUTO REDILUTE RANGES

 

 

TOP

FINGER PRICKER :

READY TO USE, DISPOSABLE PRICKER (NO SEPARATE ATTACHMENT)
TAMPER PROOF INDIVIDUAL PACKING
GAMMA RADIATION STERILIZED
PROPER GRIP  TO AVOID  CONTAMINATION
MEDICAL GRADE MATERIAL
ULTRA SHARP, CONVENIENT AND SAFE.

TOP

 

COAGULATION RANGE FROM SIGMA, USA

SR.NO. PRODUCT PACKSIZE
1. THRMBOPLASTIN WITH CALCIUM 10X4, 10X10
2. APTT 10X2, 10X10
3. COAGULATION CONTROL- I 10X1
4. COAGULATION CONTROL- II 10X1
5. COAGULATION CONTROL- III 10X1
6. D-DIMER KIT 80 ASSAY
7. ATOXIN 3X1, 10X1
8. THROMBIN REAGENT 6X6
9. PLATELATE AGGREGATION KIT 60 ASSAYS
10. FACTOR DEFICIENT PLASMA-II 6X1
11 IV 6X1
12. VII 6X1
13 VIII 6X1
14 IX 6X1
15 X 6X1
16 XI 6X1
17 XII 6X1
18 XIII 4X1
19. REFERENCE PLASMA NORMAL 10X1
20. REFERENCE PLASMA ABNORMAL 10X1
21 ANTITHROMBIN III (CLOTTING) 40 ASSAYS
22 ANTITHROMBIN III 36 ASSAYS
23. PROTEIN C (CLOTTING) 45 ASSAYS
24. PROTEIN C DEFF. PLASMA 10X0.5
25. PROTEIN C 30 ASSAYS
26 COLLEGENE 3X1
27 EPINEPHERIN 3X1
28 ADP REAGENT 3X1
29. FIBNNOGEN KIT 3X1

Bio-Product (Powder) from Teco Diagnostic, USA

 

Sr.No. Product Packsize
1 CKMB 20x1
2 CPK 20x1
3 Amylase 20x1, 10x6, 5x6
4 ACP 20x1
5 Triglycerides 20x1, 20x3, 5x50, 10x15
6 Cholesterol 20x3, 5x50, 10x6
7 Gamma GT 20x1, 10x15
8 LDH 20x1
9 ALP 20x3, 20x12, 5x50
10 SGOT 20x3, 20x12, 5x50
11 Urea-BUN 20x3, 20x12, 5x50
12 Glucose 5x250
13 Uric Acid 20x12, 5x50
14 Bilirubin-D 4x120
15 Bilirubin-T 4x120
16 Creatinnine 4x120
17 GHb 20T

TOP

Liquid Stable Bio-Chemistry from Dialab - Austria.

Sr.No. Product Method Packsize
1 SGPT/OT IFCC 5X50, 5X100, 5X25, 1X25
2 CPK DGKC 5X10, 5X25, 1X20
3 Triglycerides GPO-PAP 5X50, 5X100, 5X25, 2X10
4 Cholesterol CHOD-PAP 5X50, 5X100, 5X25, 2X10
5 Gamma GT SZASZ 5X50, 5X25, 1X25
6 LDH-P OPTIMISED-DGKC 5X50, 5X25, 1X25
7 ALP IFCC 5X50, 5X100, 5X25, 1X25
8 Urea-BUN GLDH 5X50, 5X100, 5X25, 1X25
9 Glucose GOD-POD 5X50, 2X500, 5X100
10 Uric Acid TBHBA 5X50, 5X100, 5X25, 1X25
11 Bilirubin-D   4x120
12 Bilirubin-T   4x120
13 Creatinnine MODIFIED JAFFE 5X50, 5X100, 5X25
14 TOTAL PROTEIN BIURET 5X50, 5X100, 1X100
15 DIRECT LDL &HDL    
16 HDL Cholesterol PHOSPHOTUNGSTATE 2X50, 1X40, 1X25, 1X10
17 CSF / URINE PROTEIN   2X120
18 CALCIUM   6X50
19 CHLORIDE   6X50
20 PHOSPHORUS   6X50
21 CSF/URINE PROTEIN   4X50
22 BIL-T & BIL-D   6X50